Skip to content

Battery24%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

1 October 2026

Right nowor a period:
Panel 1, monocrystalline. 54 Wh over 1 October 2026, 0.19 kWh per kWp, measured for 8.3 hours.M154 WhPanel 2, monocrystalline. 59 Wh over 1 October 2026, 0.21 kWh per kWp, measured for 8.3 hours.M259 WhPanel 3, monocrystalline. 56 Wh over 1 October 2026, 0.20 kWh per kWp, measured for 8.3 hours.M356 WhPanel 4, monocrystalline. 54 Wh over 1 October 2026, 0.19 kWh per kWp, measured for 8.3 hours.M454 WhPanel 5, monocrystalline. 55 Wh over 1 October 2026, 0.20 kWh per kWp, measured for 8.3 hours.M555 WhPanel 6, monocrystalline. 55 Wh over 1 October 2026, 0.20 kWh per kWp, measured for 8.3 hours.M655 WhPanel 1, polycrystalline. 56 Wh over 1 October 2026, 0.20 kWh per kWp, measured for 8.3 hours.P156 WhPanel 2, polycrystalline. 61 Wh over 1 October 2026, 0.22 kWh per kWp, measured for 8.3 hours.P261 WhPanel 3, polycrystalline. 60 Wh over 1 October 2026, 0.22 kWh per kWp, measured for 8.3 hours.P360 WhPanel 4, polycrystalline. 53 Wh over 1 October 2026, 0.19 kWh per kWp, measured for 8.3 hours.P453 WhPanel 5, polycrystalline. 54 Wh over 1 October 2026, 0.20 kWh per kWp, measured for 8.3 hours.P554 WhPanel 6, polycrystalline. 60 Wh over 1 October 2026, 0.22 kWh per kWp, measured for 8.3 hours.P660 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 1 October 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 212 Wh/kWp
Weakest
M4, 191 Wh/kWp
Difference (calculated)
10 % less

6 of the 6 panels of this row answered. The weakest, M4, produces 10 percent less than the strongest, M2 (191 Wh/kWp against 212 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P2, 223 Wh/kWp
Weakest
P4, 194 Wh/kWp
Difference (calculated)
13 % less

6 of the 6 panels of this row answered. The weakest, P4, produces 13 percent less than the strongest, P2 (194 Wh/kWp against 223 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.