Live data
Each value says how often it is read and when it was last measured. The inverters, meters and battery are read every 5 minutes, the pyranometer every 10. The lab sends them to this site every 15 minutes, and after 30 minutes a value is marked as delayed.
- Arrays 1 and 20 W
- Vertical array0 W
- Hydropower backup0 Wone way only
- Battery84 W21 %, Giving power
- Technical roomSunny Island and inverters
- Lab appliances69 W
- Car chargers6 W
- Solar power, totalThe three arrays together, 4 770 Wp in total. A Sunny Boy shuts down when there is not enough light, and a sum with a missing term is not a smaller total, it is a wrong one. So this series has a hole whenever any inverter was asleep, which in Bergen means most of the winter afternoon.
- 0W
- Read every 5 min, last
- Global irradianceSunlight energy arriving on a horizontal surface.
- 0W/m²
- Read every 10 min, last
- Battery state of chargeHow full the 14.4 kWh Tesvolt battery is.
- 21%
- Read every 5 min, last
- ConsumptionThe lab appliances and the charging stations together. The yellow sockets, which are wired directly to the HVL grid, are not part of it.
- 74W
- Read every 5 min, last
Energy balance
Measured
Today
- Solar production (AC power of the three inverters together, W)
- Sunlight (global irradiance on a horizontal surface, pyranometer, W/m²)
- Battery (state of charge, %)
| Time (Bergen) | Solar production (W) | Sunlight (W/m²) | Battery (%) |
|---|---|---|---|
| 04/11, 07:00 | not read | not read | 21 |
| 04/11, 07:30 | not read | 0 | 21 |
| 04/11, 08:00 | not read | 0 | 22 |
| 04/11, 08:30 | not read | 2 | 23 |
| 04/11, 09:00 | 0 | 11 | 25 |
| 04/11, 09:30 | 86 | 43 | 22 |
| 04/11, 10:00 | 159 | 52 | 21 |
| 04/11, 10:30 | 437 | 108 | 24 |
| 04/11, 11:00 | 398 | 101 | 24 |
| 04/11, 11:30 | 419 | 92 | 23 |
| 04/11, 12:00 | 464 | 93 | 23 |
| 04/11, 12:30 | 1 159 | 149 | 23 |
| 04/11, 13:00 | 659 | 67 | 24 |
| 04/11, 13:30 | 2 030 | 204 | 26 |
| 04/11, 14:00 | 651 | 194 | 27 |
| 04/11, 14:30 | 758 | 143 | 27 |
| 04/11, 15:00 | 56 | 32 | 27 |
| 04/11, 15:30 | 23 | 20 | 25 |
| 04/11, 16:00 | 15 | 14 | 23 |
| 04/11, 16:30 | 0 | 6 | 22 |
Solar production
Read from each of the three inverters since 16 September 2026. An inverter switches off in low light, so early and late in the day an array can show no value.
- Solar power, array 1 (monocrystalline)6 monocrystalline panels Astronergy ASM6610M, 280 Wp each, 1 680 Wp, confirmed from the label on the back of a panel. Wired as one string of six in series since 28 March 2026. WHICH of the two tilted arrays this inverter is connected to is not confirmed: it comes from the lab wall chart, and two of the three inverters may have been exchanged about a year ago. The two tilted arrays cannot be told apart from their measurements, because six monocrystalline panels and six polycrystalline ones in series differ by three tenths of a volt.
- 0W
- Read every 5 min, last
- Solar power, array 2 (polycrystalline)6 polycrystalline panels REC275PE, 275 Wp each, 1 650 Wp. Wired as one string of six in series since 28 March 2026. WHICH of the two tilted arrays this inverter is connected to is not confirmed, for the same reason as array 1: the assignment comes from the wall chart, and two inverters may have been exchanged since it was drawn.
- 0W
- Read every 5 min, last
- Solar power, array 3 (vertical, east and west)Six frames standing vertically on the old railway rails, each carrying two MiaSole FLEX-02 120N thin film modules back to back, one facing east and one facing west. Twelve modules of 120 Wp, 1 440 Wp in total. The two faces are two strings of six wired in parallel, so the inverter reports them added together and can never tell east from west. These modules are not bifacial: a CIGS module is opaque and produces nothing through its back. It is the mounting that has two faces.
- 0W
- Read every 5 min, last
No new reading since . The logger may be offline. System status.
Battery
- Battery state of chargeHow full the 14.4 kWh Tesvolt battery is.
- 21%
- Read every 5 min, last
- Battery powerPositive when the battery is supplying the lab, negative when it is being charged. Confirmed on 16 September 2026 by watching the state of charge rise from 28 % to 30 % while this value stayed negative.
- 84W
- Read every 5 min, last
What the lab uses
The lab appliances and the two charging stations, each on its own meter, and their sum.
- ConsumptionThe lab appliances and the charging stations together. The yellow sockets, which are wired directly to the HVL grid, are not part of it.
- 74W
- Read every 5 min, last
- Lab appliancesEverything the lab itself runs: the Raspberry Pi, the screen, the network switch, the router, the backup power supply. Measured by the meter marked "Lab local grid".
- 69W
- Read every 5 min, last
- Charging stationsThe two car charging stations CC1 and CC2, measured at their own meter. It reads a few watts of standby when no car is plugged in.
- 6W
- Read every 5 min, last
Backup from the grid
Starts when the battery falls below 20 % and stops at 25 %. From October to March the lab needs it regularly.
- Backup from the gridThe lab is not connected to the grid for its normal supply, but a backup feed from the HVL grid can start when the battery falls below 20 %, and stops again at 25 %. This is what passes through it.
- 0W
- Read every 5 min, last
Weather
- Global irradianceSunlight energy arriving on a horizontal surface.
- 0W/m²
- Read every 10 min, last
- Outdoor temperatureAir temperature outside the lab, in the shade of the building. Measured on site, not taken from a forecast.
- 8.4°C
- Read every 5 min, last
- Temperature under the monocrystalline panelsAir temperature under the upper, monocrystalline row. In sunshine it runs well above the outdoor air, and a hotter cell produces less: this is the series to put against pv_power_array1.
- 6.1°C
- Read every 5 min, last
- Outdoor humidityRelative humidity outside the lab.
- 81%
- Read every 5 min, last
Inside the lab
- Indoor temperatureAir temperature inside the lab. The sensor is close to a wall and to the ventilation outlet, so it reads the corner it sits in rather than the room; moving it is on the job list of autumn 2026.
- 20.0°C
- Read every 5 min, last
- Indoor humidityRelative humidity inside the lab.
- 38%
- Read every 5 min, last
Controlled loads
The lab switches these three loads itself, once a minute, from the battery level: the fuller the battery, the more it allows itself to run, and below 23 % it protects the battery and drops them. This page only shows their state. Nothing here can switch anything on or off.
- Energy levelControl level EL0 to EL3, decided from the battery state of charge.
- No data
- Read every 5 min
- Car charger CC1Switched automatically by the battery state of charge.
- Off
- Read every 5 min, last
- Second car socket CC2Switched automatically by the battery state of charge.
- Off
- Read every 5 min, last
- Heater, 2 kWSwitched automatically by the battery state of charge.
- Off
- Read every 5 min, last
- Controlled loads, totalThe three switched loads added together, as each Shelly reports them. It reads 0 W whenever the lab has turned them all off, which is normal below 65 % of battery.
- 0W
- Read every 5 min, last
- Power drawn by CC1What the car charger actually draws, not only whether it is allowed to run.
- 0W
- Read every 5 min, last
- Power drawn by CC2What the second car socket actually draws, not only whether it is allowed to run.
- 0W
- Read every 5 min, last
- Power drawn by the heater, 2 kWWhat the heater actually draws, not only whether it is allowed to run.
- 0W
- Read every 5 min, last
Any day, week, month or year, as a graph or a table, and downloadable as a CSV with its metadata.