Battery22%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

2 October 2026

Right nowor a period:
Panel 1, monocrystalline. 269 Wh over 2 October 2026, 0.96 kWh per kWp, measured for 2.9 hours.M1269 WhPanel 2, monocrystalline. 277 Wh over 2 October 2026, 0.99 kWh per kWp, measured for 2.9 hours.M2277 WhPanel 3, monocrystalline. 274 Wh over 2 October 2026, 0.98 kWh per kWp, measured for 2.9 hours.M3274 WhPanel 4, monocrystalline. 270 Wh over 2 October 2026, 0.97 kWh per kWp, measured for 2.9 hours.M4270 WhPanel 5, monocrystalline. 268 Wh over 2 October 2026, 0.96 kWh per kWp, measured for 2.9 hours.M5268 WhPanel 6, monocrystalline. 272 Wh over 2 October 2026, 0.97 kWh per kWp, measured for 2.9 hours.M6272 WhPanel 1, polycrystalline. 295 Wh over 2 October 2026, 1.07 kWh per kWp, measured for 2.9 hours.P1295 WhPanel 2, polycrystalline. 294 Wh over 2 October 2026, 1.07 kWh per kWp, measured for 2.9 hours.P2294 WhPanel 3, polycrystalline. 294 Wh over 2 October 2026, 1.07 kWh per kWp, measured for 2.9 hours.P3294 WhPanel 4, polycrystalline. 296 Wh over 2 October 2026, 1.08 kWh per kWp, measured for 2.9 hours.P4296 WhPanel 5, polycrystalline. 298 Wh over 2 October 2026, 1.08 kWh per kWp, measured for 2.9 hours.P5298 WhPanel 6, polycrystalline. 302 Wh over 2 October 2026, 1.10 kWh per kWp, measured for 2.9 hours.P6302 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 2 October 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 990 Wh/kWp
Weakest
M5, 956 Wh/kWp
Difference (calculated)
3 % less

6 of the 6 panels of this row answered. The weakest, M5, produces 3 percent less than the strongest, M2 (956 Wh/kWp against 990 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P6, 1 098 Wh/kWp
Weakest
P3, 1 067 Wh/kWp
Difference (calculated)
3 % less

6 of the 6 panels of this row answered. The weakest, P3, produces 3 percent less than the strongest, P6 (1 067 Wh/kWp against 1 098 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.