Skip to content

Battery24%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

4 November 2026

Right nowor a period:
Panel 1, monocrystalline. 185 Wh over 4 November 2026, 0.66 kWh per kWp, measured for 5.2 hours.M1185 WhPanel 2, monocrystalline. 190 Wh over 4 November 2026, 0.68 kWh per kWp, measured for 5.2 hours.M2190 WhPanel 3, monocrystalline. 188 Wh over 4 November 2026, 0.67 kWh per kWp, measured for 5.2 hours.M3188 WhPanel 4, monocrystalline. 189 Wh over 4 November 2026, 0.68 kWh per kWp, measured for 5.1 hours.M4189 WhPanel 5, monocrystalline. 181 Wh over 4 November 2026, 0.65 kWh per kWp, measured for 5.2 hours.M5181 WhPanel 6, monocrystalline. 171 Wh over 4 November 2026, 0.61 kWh per kWp, measured for 5.1 hours.M6171 WhPanel 1, polycrystalline. 259 Wh over 4 November 2026, 0.94 kWh per kWp, measured for 5.2 hours.P1259 WhPanel 2, polycrystalline. 256 Wh over 4 November 2026, 0.93 kWh per kWp, measured for 5.2 hours.P2256 WhPanel 3, polycrystalline. 252 Wh over 4 November 2026, 0.92 kWh per kWp, measured for 5.2 hours.P3252 WhPanel 4, polycrystalline. 251 Wh over 4 November 2026, 0.91 kWh per kWp, measured for 5.2 hours.P4251 WhPanel 5, polycrystalline. 236 Wh over 4 November 2026, 0.86 kWh per kWp, measured for 5.2 hours.P5236 WhPanel 6, polycrystalline. 233 Wh over 4 November 2026, 0.85 kWh per kWp, measured for 5.2 hours.P6233 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 4 November 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 679 Wh/kWp
Weakest
M6, 612 Wh/kWp
Difference (calculated)
10 % less

6 of the 6 panels of this row answered. The weakest, M6, produces 10 percent less than the strongest, M2 (612 Wh/kWp against 679 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P1, 940 Wh/kWp
Weakest
P6, 846 Wh/kWp
Difference (calculated)
10 % less

6 of the 6 panels of this row answered. The weakest, P6, produces 10 percent less than the strongest, P1 (846 Wh/kWp against 940 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.