Skip to content

Battery22%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

30 September 2026

Right nowor a period:
Panel 1, monocrystalline. 710 Wh over 30 September 2026, 2.53 kWh per kWp, measured for 7.5 hours.M1710 WhPanel 2, monocrystalline. 696 Wh over 30 September 2026, 2.48 kWh per kWp, measured for 7.5 hours.M2696 WhPanel 3, monocrystalline. 685 Wh over 30 September 2026, 2.45 kWh per kWp, measured for 7.5 hours.M3685 WhPanel 4, monocrystalline. 678 Wh over 30 September 2026, 2.42 kWh per kWp, measured for 7.5 hours.M4678 WhPanel 5, monocrystalline. 660 Wh over 30 September 2026, 2.36 kWh per kWp, measured for 7.5 hours.M5660 WhPanel 6, monocrystalline. 627 Wh over 30 September 2026, 2.24 kWh per kWp, measured for 7.5 hours.M6627 WhPanel 1, polycrystalline. 743 Wh over 30 September 2026, 2.70 kWh per kWp, measured for 7.5 hours.P1743 WhPanel 2, polycrystalline. 726 Wh over 30 September 2026, 2.64 kWh per kWp, measured for 7.5 hours.P2726 WhPanel 3, polycrystalline. 705 Wh over 30 September 2026, 2.56 kWh per kWp, measured for 7.5 hours.P3705 WhPanel 4, polycrystalline. 702 Wh over 30 September 2026, 2.55 kWh per kWp, measured for 7.5 hours.P4702 WhPanel 5, polycrystalline. 695 Wh over 30 September 2026, 2.53 kWh per kWp, measured for 7.5 hours.P5695 WhPanel 6, polycrystalline. 681 Wh over 30 September 2026, 2.47 kWh per kWp, measured for 7.5 hours.P6681 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 30 September 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M1, 2 534 Wh/kWp
Weakest
M6, 2 239 Wh/kWp
Difference (calculated)
12 % less

6 of the 6 panels of this row answered. The weakest, M6, produces 12 percent less than the strongest, M1 (2 239 Wh/kWp against 2 534 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P1, 2 702 Wh/kWp
Weakest
P6, 2 475 Wh/kWp
Difference (calculated)
8 % less

6 of the 6 panels of this row answered. The weakest, P6, produces 8 percent less than the strongest, P1 (2 475 Wh/kWp against 2 702 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.