Skip to content

Battery24%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

29 September 2026

Right nowor a period:
Panel 1, monocrystalline. 841 Wh over 29 September 2026, 3.00 kWh per kWp, measured for 7.4 hours.M1841 WhPanel 2, monocrystalline. 840 Wh over 29 September 2026, 3.00 kWh per kWp, measured for 7.3 hours.M2840 WhPanel 3, monocrystalline. 819 Wh over 29 September 2026, 2.93 kWh per kWp, measured for 7.3 hours.M3819 WhPanel 4, monocrystalline. 772 Wh over 29 September 2026, 2.76 kWh per kWp, measured for 7.3 hours.M4772 WhPanel 5, monocrystalline. 721 Wh over 29 September 2026, 2.57 kWh per kWp, measured for 7.3 hours.M5721 WhPanel 6, monocrystalline. 674 Wh over 29 September 2026, 2.41 kWh per kWp, measured for 7.3 hours.M6674 WhPanel 1, polycrystalline. 886 Wh over 29 September 2026, 3.22 kWh per kWp, measured for 7.4 hours.P1886 WhPanel 2, polycrystalline. 862 Wh over 29 September 2026, 3.13 kWh per kWp, measured for 7.4 hours.P2862 WhPanel 3, polycrystalline. 845 Wh over 29 September 2026, 3.07 kWh per kWp, measured for 7.4 hours.P3845 WhPanel 4, polycrystalline. 810 Wh over 29 September 2026, 2.94 kWh per kWp, measured for 7.4 hours.P4810 WhPanel 5, polycrystalline. 766 Wh over 29 September 2026, 2.78 kWh per kWp, measured for 7.4 hours.P5766 WhPanel 6, polycrystalline. 743 Wh over 29 September 2026, 2.70 kWh per kWp, measured for 7.4 hours.P6743 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 29 September 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M1, 3 003 Wh/kWp
Weakest
M6, 2 407 Wh/kWp
Difference (calculated)
20 % less

6 of the 6 panels of this row answered. The weakest, M6, produces 20 percent less than the strongest, M1 (2 407 Wh/kWp against 3 003 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P1, 3 222 Wh/kWp
Weakest
P6, 2 702 Wh/kWp
Difference (calculated)
16 % less

6 of the 6 panels of this row answered. The weakest, P6, produces 16 percent less than the strongest, P1 (2 702 Wh/kWp against 3 222 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.