Skip to content

Battery21%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

1 November 2026

Right nowor a period:
Panel 1, monocrystalline. 307 Wh over 1 November 2026, 1.10 kWh per kWp, measured for 5.4 hours.M1307 WhPanel 2, monocrystalline. 319 Wh over 1 November 2026, 1.14 kWh per kWp, measured for 5.4 hours.M2319 WhPanel 3, monocrystalline. 309 Wh over 1 November 2026, 1.10 kWh per kWp, measured for 5.4 hours.M3309 WhPanel 4, monocrystalline. 302 Wh over 1 November 2026, 1.08 kWh per kWp, measured for 5.4 hours.M4302 WhPanel 5, monocrystalline. 301 Wh over 1 November 2026, 1.08 kWh per kWp, measured for 5.4 hours.M5301 WhPanel 6, monocrystalline. 298 Wh over 1 November 2026, 1.07 kWh per kWp, measured for 5.4 hours.M6298 WhPanel 1, polycrystalline. 489 Wh over 1 November 2026, 1.78 kWh per kWp, measured for 5.5 hours.P1489 WhPanel 2, polycrystalline. 472 Wh over 1 November 2026, 1.72 kWh per kWp, measured for 5.5 hours.P2472 WhPanel 3, polycrystalline. 452 Wh over 1 November 2026, 1.65 kWh per kWp, measured for 5.5 hours.P3452 WhPanel 4, polycrystalline. 451 Wh over 1 November 2026, 1.64 kWh per kWp, measured for 5.5 hours.P4451 WhPanel 5, polycrystalline. 446 Wh over 1 November 2026, 1.62 kWh per kWp, measured for 5.5 hours.P5446 WhPanel 6, polycrystalline. 451 Wh over 1 November 2026, 1.64 kWh per kWp, measured for 5.5 hours.P6451 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 1 November 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 1 141 Wh/kWp
Weakest
M6, 1 065 Wh/kWp
Difference (calculated)
7 % less

6 of the 6 panels of this row answered. The weakest, M6, produces 7 percent less than the strongest, M2 (1 065 Wh/kWp against 1 141 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P1, 1 778 Wh/kWp
Weakest
P5, 1 623 Wh/kWp
Difference (calculated)
9 % less

6 of the 6 panels of this row answered. The weakest, P5, produces 9 percent less than the strongest, P1 (1 623 Wh/kWp against 1 778 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.