Skip to content

Battery22%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

Week 44, 2026

Right nowor a period:
Panel 1, monocrystalline. 586 Wh over Week 44, 2026, 2.09 kWh per kWp, measured for 32.8 hours.M1586 WhPanel 2, monocrystalline. 626 Wh over Week 44, 2026, 2.24 kWh per kWp, measured for 33.0 hours.M2626 WhPanel 3, monocrystalline. 595 Wh over Week 44, 2026, 2.12 kWh per kWp, measured for 33.0 hours.M3595 WhPanel 4, monocrystalline. 590 Wh over Week 44, 2026, 2.11 kWh per kWp, measured for 33.0 hours.M4590 WhPanel 5, monocrystalline. 582 Wh over Week 44, 2026, 2.08 kWh per kWp, measured for 33.0 hours.M5582 WhPanel 6, monocrystalline. 574 Wh over Week 44, 2026, 2.05 kWh per kWp, measured for 33.0 hours.M6574 WhPanel 1, polycrystalline. 821 Wh over Week 44, 2026, 2.99 kWh per kWp, measured for 33.2 hours.P1821 WhPanel 2, polycrystalline. 815 Wh over Week 44, 2026, 2.96 kWh per kWp, measured for 33.2 hours.P2815 WhPanel 3, polycrystalline. 791 Wh over Week 44, 2026, 2.88 kWh per kWp, measured for 33.3 hours.P3791 WhPanel 4, polycrystalline. 757 Wh over Week 44, 2026, 2.75 kWh per kWp, measured for 33.3 hours.P4757 WhPanel 5, polycrystalline. 743 Wh over Week 44, 2026, 2.70 kWh per kWp, measured for 33.3 hours.P5743 WhPanel 6, polycrystalline. 762 Wh over Week 44, 2026, 2.77 kWh per kWp, measured for 33.3 hours.P6762 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over Week 44, 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 2 237 Wh/kWp
Weakest
M6, 2 049 Wh/kWp
Difference (calculated)
8 % less

6 of the 6 panels of this row answered. The weakest, M6, produces 8 percent less than the strongest, M2 (2 049 Wh/kWp against 2 237 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P1, 2 986 Wh/kWp
Weakest
P5, 2 703 Wh/kWp
Difference (calculated)
9 % less

6 of the 6 panels of this row answered. The weakest, P5, produces 9 percent less than the strongest, P1 (2 703 Wh/kWp against 2 986 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.