Skip to content

Battery23%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

23 October 2026

Right nowor a period:
Panel 1, monocrystalline. 110 Wh over 23 October 2026, 0.39 kWh per kWp, measured for 6.3 hours.M1110 WhPanel 2, monocrystalline. 113 Wh over 23 October 2026, 0.40 kWh per kWp, measured for 6.3 hours.M2113 WhPanel 3, monocrystalline. 112 Wh over 23 October 2026, 0.40 kWh per kWp, measured for 6.3 hours.M3112 WhPanel 4, monocrystalline. 109 Wh over 23 October 2026, 0.39 kWh per kWp, measured for 6.3 hours.M4109 WhPanel 5, monocrystalline. 110 Wh over 23 October 2026, 0.39 kWh per kWp, measured for 6.3 hours.M5110 WhPanel 6, monocrystalline. 109 Wh over 23 October 2026, 0.39 kWh per kWp, measured for 6.3 hours.M6109 WhPanel 1, polycrystalline. 116 Wh over 23 October 2026, 0.42 kWh per kWp, measured for 6.3 hours.P1116 WhPanel 2, polycrystalline. 119 Wh over 23 October 2026, 0.43 kWh per kWp, measured for 6.3 hours.P2119 WhPanel 3, polycrystalline. 117 Wh over 23 October 2026, 0.43 kWh per kWp, measured for 6.3 hours.P3117 WhPanel 4, polycrystalline. 113 Wh over 23 October 2026, 0.41 kWh per kWp, measured for 6.3 hours.P4113 WhPanel 5, polycrystalline. 113 Wh over 23 October 2026, 0.41 kWh per kWp, measured for 6.3 hours.P5113 WhPanel 6, polycrystalline. 117 Wh over 23 October 2026, 0.43 kWh per kWp, measured for 6.3 hours.P6117 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 23 October 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 405 Wh/kWp
Weakest
M6, 388 Wh/kWp
Difference (calculated)
4 % less

6 of the 6 panels of this row answered. The weakest, M6, produces 4 percent less than the strongest, M2 (388 Wh/kWp against 405 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P2, 432 Wh/kWp
Weakest
P4, 411 Wh/kWp
Difference (calculated)
5 % less

6 of the 6 panels of this row answered. The weakest, P4, produces 5 percent less than the strongest, P2 (411 Wh/kWp against 432 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.