Skip to content

Battery24%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

20 October 2026

Right nowor a period:
Panel 1, monocrystalline. 573 Wh over 20 October 2026, 2.04 kWh per kWp, measured for 4.7 hours.M1573 WhPanel 2, monocrystalline. 581 Wh over 20 October 2026, 2.07 kWh per kWp, measured for 4.7 hours.M2581 WhPanel 3, monocrystalline. 573 Wh over 20 October 2026, 2.05 kWh per kWp, measured for 4.7 hours.M3573 WhPanel 4, monocrystalline. 523 Wh over 20 October 2026, 1.87 kWh per kWp, measured for 4.7 hours.M4523 WhPanel 5, monocrystalline. 503 Wh over 20 October 2026, 1.80 kWh per kWp, measured for 4.7 hours.M5503 WhPanel 6, monocrystalline. 467 Wh over 20 October 2026, 1.67 kWh per kWp, measured for 4.7 hours.M6467 WhPanel 1, polycrystalline. 621 Wh over 20 October 2026, 2.26 kWh per kWp, measured for 4.7 hours.P1621 WhPanel 2, polycrystalline. 607 Wh over 20 October 2026, 2.21 kWh per kWp, measured for 4.7 hours.P2607 WhPanel 3, polycrystalline. 596 Wh over 20 October 2026, 2.17 kWh per kWp, measured for 4.7 hours.P3596 WhPanel 4, polycrystalline. 566 Wh over 20 October 2026, 2.06 kWh per kWp, measured for 4.7 hours.P4566 WhPanel 5, polycrystalline. 556 Wh over 20 October 2026, 2.02 kWh per kWp, measured for 4.7 hours.P5556 WhPanel 6, polycrystalline. 519 Wh over 20 October 2026, 1.89 kWh per kWp, measured for 4.7 hours.P6519 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 20 October 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 2 074 Wh/kWp
Weakest
M6, 1 666 Wh/kWp
Difference (calculated)
20 % less

6 of the 6 panels of this row answered. The weakest, M6, produces 20 percent less than the strongest, M2 (1 666 Wh/kWp against 2 074 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P1, 2 260 Wh/kWp
Weakest
P6, 1 888 Wh/kWp
Difference (calculated)
16 % less

6 of the 6 panels of this row answered. The weakest, P6, produces 16 percent less than the strongest, P1 (1 888 Wh/kWp against 2 260 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.