Skip to content

Battery23%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

17 October 2026

Right nowor a period:
Panel 1, monocrystalline. 577 Wh over 17 October 2026, 2.06 kWh per kWp, measured for 7.0 hours.M1577 WhPanel 2, monocrystalline. 593 Wh over 17 October 2026, 2.12 kWh per kWp, measured for 7.1 hours.M2593 WhPanel 3, monocrystalline. 586 Wh over 17 October 2026, 2.09 kWh per kWp, measured for 6.9 hours.M3586 WhPanel 4, monocrystalline. 597 Wh over 17 October 2026, 2.13 kWh per kWp, measured for 7.0 hours.M4597 WhPanel 5, monocrystalline. 597 Wh over 17 October 2026, 2.13 kWh per kWp, measured for 7.0 hours.M5597 WhPanel 6, monocrystalline. 586 Wh over 17 October 2026, 2.09 kWh per kWp, measured for 7.0 hours.M6586 WhPanel 1, polycrystalline. 606 Wh over 17 October 2026, 2.20 kWh per kWp, measured for 7.1 hours.P1606 WhPanel 2, polycrystalline. 617 Wh over 17 October 2026, 2.24 kWh per kWp, measured for 7.1 hours.P2617 WhPanel 3, polycrystalline. 621 Wh over 17 October 2026, 2.26 kWh per kWp, measured for 7.1 hours.P3621 WhPanel 4, polycrystalline. 625 Wh over 17 October 2026, 2.27 kWh per kWp, measured for 7.1 hours.P4625 WhPanel 5, polycrystalline. 621 Wh over 17 October 2026, 2.26 kWh per kWp, measured for 7.1 hours.P5621 WhPanel 6, polycrystalline. 627 Wh over 17 October 2026, 2.28 kWh per kWp, measured for 7.1 hours.P6627 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 17 October 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M4, 2 132 Wh/kWp
Weakest
M1, 2 062 Wh/kWp
Difference (calculated)
3 % less

6 of the 6 panels of this row answered. The weakest, M1, produces 3 percent less than the strongest, M4 (2 062 Wh/kWp against 2 132 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P6, 2 280 Wh/kWp
Weakest
P1, 2 204 Wh/kWp
Difference (calculated)
3 % less

6 of the 6 panels of this row answered. The weakest, P1, produces 3 percent less than the strongest, P6 (2 204 Wh/kWp against 2 280 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.