Skip to content

Battery24%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

9 October 2026

Right nowor a period:
Panel 1, monocrystalline. 158 Wh over 9 October 2026, 0.56 kWh per kWp, measured for 6.0 hours.M1158 WhPanel 2, monocrystalline. 163 Wh over 9 October 2026, 0.58 kWh per kWp, measured for 6.0 hours.M2163 WhPanel 3, monocrystalline. 162 Wh over 9 October 2026, 0.58 kWh per kWp, measured for 6.0 hours.M3162 WhPanel 4, monocrystalline. 160 Wh over 9 October 2026, 0.57 kWh per kWp, measured for 6.0 hours.M4160 WhPanel 5, monocrystalline. 158 Wh over 9 October 2026, 0.57 kWh per kWp, measured for 6.0 hours.M5158 WhPanel 6, monocrystalline. 149 Wh over 9 October 2026, 0.53 kWh per kWp, measured for 5.8 hours.M6149 WhPanel 1, polycrystalline. 166 Wh over 9 October 2026, 0.60 kWh per kWp, measured for 6.0 hours.P1166 WhPanel 2, polycrystalline. 168 Wh over 9 October 2026, 0.61 kWh per kWp, measured for 6.0 hours.P2168 WhPanel 3, polycrystalline. 159 Wh over 9 October 2026, 0.58 kWh per kWp, measured for 5.9 hours.P3159 WhPanel 4, polycrystalline. 162 Wh over 9 October 2026, 0.59 kWh per kWp, measured for 6.0 hours.P4162 WhPanel 5, polycrystalline. 162 Wh over 9 October 2026, 0.59 kWh per kWp, measured for 6.0 hours.P5162 WhPanel 6, polycrystalline. 166 Wh over 9 October 2026, 0.61 kWh per kWp, measured for 6.0 hours.P6166 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 9 October 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 583 Wh/kWp
Weakest
M6, 532 Wh/kWp
Difference (calculated)
9 % less

6 of the 6 panels of this row answered. The weakest, M6, produces 9 percent less than the strongest, M2 (532 Wh/kWp against 583 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P2, 611 Wh/kWp
Weakest
P3, 577 Wh/kWp
Difference (calculated)
6 % less

6 of the 6 panels of this row answered. The weakest, P3, produces 6 percent less than the strongest, P2 (577 Wh/kWp against 611 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.