Panel 1, monocrystalline. 535 Wh over 8 October 2026, 1.91 kWh per kWp, measured for 7.0 hours.M1535 WhPanel 2, monocrystalline. 552 Wh over 8 October 2026, 1.97 kWh per kWp, measured for 7.0 hours.M2552 WhPanel 3, monocrystalline. 566 Wh over 8 October 2026, 2.02 kWh per kWp, measured for 6.9 hours.M3566 WhPanel 4, monocrystalline. 577 Wh over 8 October 2026, 2.06 kWh per kWp, measured for 7.0 hours.M4577 WhPanel 5, monocrystalline. 585 Wh over 8 October 2026, 2.09 kWh per kWp, measured for 7.0 hours.M5585 WhPanel 6, monocrystalline. 577 Wh over 8 October 2026, 2.06 kWh per kWp, measured for 6.9 hours.M6577 WhPanel 1, polycrystalline. 607 Wh over 8 October 2026, 2.21 kWh per kWp, measured for 7.1 hours.P1607 WhPanel 2, polycrystalline. 608 Wh over 8 October 2026, 2.21 kWh per kWp, measured for 7.0 hours.P2608 WhPanel 3, polycrystalline. 600 Wh over 8 October 2026, 2.18 kWh per kWp, measured for 7.1 hours.P3600 WhPanel 4, polycrystalline. 598 Wh over 8 October 2026, 2.17 kWh per kWp, measured for 7.1 hours.P4598 WhPanel 5, polycrystalline. 604 Wh over 8 October 2026, 2.20 kWh per kWp, measured for 7.1 hours.P5604 WhPanel 6, polycrystalline. 608 Wh over 8 October 2026, 2.21 kWh per kWp, measured for 7.1 hours.P6608 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 8 October 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M5, 2 089 Wh/kWp
Weakest
M1, 1 911 Wh/kWp
Difference (calculated)
9 % less

6 of the 6 panels of this row answered. The weakest, M1, produces 9 percent less than the strongest, M5 (1 911 Wh/kWp against 2 089 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P2, 2 212 Wh/kWp
Weakest
P4, 2 174 Wh/kWp
Difference (calculated)
2 % less

6 of the 6 panels of this row answered. The weakest, P4, produces 2 percent less than the strongest, P2 (2 174 Wh/kWp against 2 212 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.