Skip to content

Battery21%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

23 September 2026

Right nowor a period:
Panel 1, monocrystalline. 51 Wh over 23 September 2026, 0.18 kWh per kWp, measured for 6.8 hours.M151 WhPanel 2, monocrystalline. 55 Wh over 23 September 2026, 0.20 kWh per kWp, measured for 6.8 hours.M255 WhPanel 3, monocrystalline. 53 Wh over 23 September 2026, 0.19 kWh per kWp, measured for 6.8 hours.M353 WhPanel 4, monocrystalline. 50 Wh over 23 September 2026, 0.18 kWh per kWp, measured for 6.8 hours.M450 WhPanel 5, monocrystalline. 52 Wh over 23 September 2026, 0.18 kWh per kWp, measured for 6.8 hours.M552 WhPanel 6, monocrystalline. 52 Wh over 23 September 2026, 0.19 kWh per kWp, measured for 6.8 hours.M652 WhPanel 1, polycrystalline. 52 Wh over 23 September 2026, 0.19 kWh per kWp, measured for 6.8 hours.P152 WhPanel 2, polycrystalline. 55 Wh over 23 September 2026, 0.20 kWh per kWp, measured for 6.8 hours.P255 WhPanel 3, polycrystalline. 54 Wh over 23 September 2026, 0.19 kWh per kWp, measured for 6.8 hours.P354 WhPanel 4, polycrystalline. 49 Wh over 23 September 2026, 0.18 kWh per kWp, measured for 6.8 hours.P449 WhPanel 5, polycrystalline. 49 Wh over 23 September 2026, 0.18 kWh per kWp, measured for 6.8 hours.P549 WhPanel 6, polycrystalline. 54 Wh over 23 September 2026, 0.20 kWh per kWp, measured for 6.8 hours.P654 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 23 September 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 197 Wh/kWp
Weakest
M4, 180 Wh/kWp
Difference (calculated)
9 % less

6 of the 6 panels of this row answered. The weakest, M4, produces 9 percent less than the strongest, M2 (180 Wh/kWp against 197 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P2, 201 Wh/kWp
Weakest
P4, 178 Wh/kWp
Difference (calculated)
11 % less

6 of the 6 panels of this row answered. The weakest, P4, produces 11 percent less than the strongest, P2 (178 Wh/kWp against 201 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.