Skip to content

Battery22%

Measured

Panel by panel

Twelve of the 24 panels have their own optimiser, so each one is measured on its own. Here they are on a photo of the frame, right now or over any period you choose.

19 September 2026

Right nowor a period:
Panel 1, monocrystalline. 63 Wh over 19 September 2026, 0.22 kWh per kWp, measured for 6.8 hours.M163 WhPanel 2, monocrystalline. 68 Wh over 19 September 2026, 0.24 kWh per kWp, measured for 6.9 hours.M268 WhPanel 3, monocrystalline. 64 Wh over 19 September 2026, 0.23 kWh per kWp, measured for 6.8 hours.M364 WhPanel 4, monocrystalline. 62 Wh over 19 September 2026, 0.22 kWh per kWp, measured for 6.8 hours.M462 WhPanel 5, monocrystalline. 63 Wh over 19 September 2026, 0.23 kWh per kWp, measured for 6.8 hours.M563 WhPanel 6, monocrystalline. 62 Wh over 19 September 2026, 0.22 kWh per kWp, measured for 6.8 hours.M662 WhPanel 1, polycrystalline. 64 Wh over 19 September 2026, 0.23 kWh per kWp, measured for 6.8 hours.P164 WhPanel 2, polycrystalline. 68 Wh over 19 September 2026, 0.25 kWh per kWp, measured for 6.8 hours.P268 WhPanel 3, polycrystalline. 66 Wh over 19 September 2026, 0.24 kWh per kWp, measured for 6.8 hours.P366 WhPanel 4, polycrystalline. 61 Wh over 19 September 2026, 0.22 kWh per kWp, measured for 6.8 hours.P461 WhPanel 5, polycrystalline. 62 Wh over 19 September 2026, 0.23 kWh per kWp, measured for 6.9 hours.P562 WhPanel 6, polycrystalline. 67 Wh over 19 September 2026, 0.24 kWh per kWp, measured for 6.8 hours.P667 Wh
The tilted frame seen from the lawn, photographed on 17 September 2026. Each panel carries what it produced over 19 September 2026.
Tint: energy per kilowatt peak, compared with the best of the twelve over this period.under 80 %80 to 90 %90 to 95 %95 to 99 %99 % and over

How even is each row

How much less the weakest panel of a row produces than the strongest, in percent of the strongest. This is a calculation made from the twelve measurements above, not a measurement of its own.

The six panels of a row see the same sky, so they should produce about the same share of their peak power. One that falls behind points to shade, dirt, snow or a fault. Over a period, a passing cloud no longer matters.

Upper row, monocrystalline

Strongest
M2, 242 Wh/kWp
Weakest
M6, 222 Wh/kWp
Difference (calculated)
8 % less

6 of the 6 panels of this row answered. The weakest, M6, produces 8 percent less than the strongest, M2 (222 Wh/kWp against 242 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

Lower row, polycrystalline

Strongest
P2, 247 Wh/kWp
Weakest
P4, 222 Wh/kWp
Difference (calculated)
10 % less

6 of the 6 panels of this row answered. The weakest, P4, produces 10 percent less than the strongest, P2 (222 Wh/kWp against 247 Wh/kWp). Over a period, a difference above about 5 percent deserves a look at that panel.

How to read these numbers

  • Direct current, before the inverter. The inverter loses a few percent, so the sum of these panels is more than the lab delivers. The real production is on the live page.
  • The vertical array is not shown. Its twelve modules have no optimiser, so they are only measured together, as array 3.
  • Read through Tigo. The optimisers report to the Tigo cloud and this site reads the values from there.

Each panel's history can be charted and downloaded on the data page. The three arrays are compared on key figures and records.